LV426841

Circuit Breaker Accessory, 24VAC, Schneider PowerPact B-Frame Series Circuit Breakers

SQUARE D BY SCHNEIDER ELECTRIC LV426841
360°
×
×

Image is for illustrative purposes only. Please refer to product description.

Manufacturer Part No:
LV426841
Newark Part No.:
16AC9389
Product Range
PowerPact Series
Technical Datasheet:
LV426841   Datasheet
See all Technical Docs

Product Range Selector (PowerPact Series)

See all from this product range

Product Information

Want to see similar products? Simply select your required attributes below and hit the button ×


:
Schneider PowerPact B-Frame Series Circuit Breakers

:
Shunt Trip (MX)

:
PowerPact Series

Find similar products Choose and modify the attributes above to find similar products.

Technical Documents (4)

CAD Downloads

×

Terms and Conditions

CAD Models - Notice
CAD Models and drawings are provided to you on a revocable limited licence for your internal use only but remain the property of the manufacturer who retain all intellectual property rights and ownership. They are provided to assist you in decision making and as design guide but are not guaranteed to be error free, accurate or up to date and is not intended to be taken as advice.
Use of these CAD models and other options provided are downloaded and used entirely at your own risk and by continuing you confirm acceptance of the above.

Accept Cancel

Product Overview

The LV426841 from Square D by Schneider Electric is a shunt trip (MX). Shunt trip serves primarily for remote, emergency off commands. It trips the circuit breaker when the control voltage rises above 70% of its rated voltage (Un). Control signals can be impulse type of ≥ 20ms or maintained control signals. An 110VAC to 130VAC shunt trip is suitable for ground fault protection when combined with a Class I ground fault sensing element. The circuit breaker must be reset locally after being tripped by shunt trip (MX). MX voltage releases comply with UL 489, CSA C22.2 number 5 and IEC 60947-2 standards. Listed for field installation per UL file E103955 and certified under CSA file 177007. Tripping by the shunt trip has priority over manual closing in the presence of a standing trip order such an action does not result in any closing even temporarily of the main contacts.
  • Control circuit voltage is 24VAC, 24VDC
  • Impulse, maintained control signal type
  • Range compatibility with PowerPact B, Compact NSXm circuit breakers
  • Impulse duration is greater than or equal to 20ms, clip-on mounting mode
  • Threshold tripping voltage is 0.7 Un during opening time
  • Continuous duty rated coil
  • Endurance is 50% of the rated mechanical endurance of the circuit breaker
  • Auxiliary connection terminal is spring
  • Response time is less than 50ms, wire stripping length is 0.31inch (8mm)

Applications

Automation & Process Control, Industrial

Available for back order

Supplier Direct Ship

Non-Cancelable / Non Returnable

Due to market conditions delivery times are for general guidance only and may be subject to change at short notice

Sorry we currently don't know when this stock will be available but you can reserve it now by placing it on back order


Pricing is unavailable. Please contact customer services.

Price for:
Each
Multiple: 1 Minimum: 1
Quantity Price Your Price
 
 
 
 

Pricing is unavailable. Please contact customer services.

No longer stocked:: No Longer Manufactured::
Add
Add
Restricted Item
Enter Your Part No/Line Note
Total Price:
Total Price: ( )
Total Price: --