Safety Light Curtains :
2 383 produit(s) trouvé(s)Tous les filtres
Tout développer
Fabricant
(162)
(1686)
(73)
(92)
(1)
(1)
(3)
(49)
(272)
Performance Level
(36)
(25)
(542)
Safety Curtain Category
(120)
(580)
Safety Integrity Level
(20)
(16)
(25)
(281)
(89)
(168)
No. of Beams
(4)
(12)
(14)
(19)
(2)
(2)
(12)
(4)
Protection Height
(1)
(1)
(1)
(4)
(2)
(6)
(8)
(4)
Sensing Range Max
(1)
(1)
(17)
(1)
(3)
(20)
(50)
(57)
IP Rating
(1)
(16)
(143)
(8)
(321)
(32)
(49)
(13)
Approvals / Standards
(46)
(1)
(121)
(8)
(13)
(52)
(44)
(8)
Beam Spacing
(3)
(27)
(72)
(1)
(18)
(38)
(12)
(8)
Control Output Type
(1)
(321)
(1)
(1)
(78)
(56)
(82)
(1)
Emballage
(2383)
| Comparer | Réf. fabricant | Code Commande | Fabricant / Description | Disponibilité | Prix pour | Prix | Quantité | Performance Level | Safety Curtain Category | Safety Integrity Level | No. of Beams | Protection Height | Sensing Range Max | IP Rating | IP Rating | Approvals / Standards | Beam Spacing | Control Output Type | Supply Voltage Max | Product Range |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | 1+1 065,650 $ 3+1 008,160 $ 5+950,670 $ 10+937,810 $ | PL c | Level 2 | SIL1, SIL CL1 | 4 | 910mm | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | 300mm | 2PNP | 24VDC | SLC2 Series | ||||||
05AN2653 | Each | 1+2 404,730 $ 5+2 343,210 $ | PL e | Level 4 | SIL3 | 12 | 920mm | 20m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 80mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
Each | 1+2 440,290 $ | PL e | Level 4 | SIL3, SIL CL3 | 61 | 1.21m | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC4 Series | ||||||
05AN2655 | Each | 1+2 709,100 $ 5+2 639,610 $ | PL e | Level 4 | SIL3 | 48 | 960mm | 20m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 20mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
05AN2661 | Each | 1+4 321,180 $ | PL e | Level 4 | SIL3 | 159 | 1.6m | 10m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 10mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
05AN2647 | Each | 1+2 040,950 $ 5+1 988,410 $ | PL e | Level 4 | SIL3 | 28 | 560mm | 20m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 20mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
Each | 1+3 491,090 $ 3+3 447,760 $ 5+3 404,430 $ | PL e | Level 4 | SIL3, SIL CL3 | 105 | 1.06m | 6m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC4 Series | ||||||
Each | 1+1 446,480 $ 3+1 390,340 $ 5+1 334,200 $ 10+1 299,040 $ | PL e | Level 4 | SIL3, SIL CL3 | 3 | 810mm | 20m | IP65, IP67 | - | CE, UKCA, cULus, TUV | 400mm | 2PNP | 24VDC | SLC4 Series | ||||||
Each | 1+2 368,620 $ 3+2 364,820 $ 5+2 361,030 $ | PL c | Level 2 | SIL1, SIL CL1 | 83 | 1.66m | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC2 Series | ||||||
Each | 1+1 610,440 $ 3+1 544,220 $ 5+1 478,000 $ | PL e | Level 4 | SIL3, SIL CL3 | 31 | 610mm | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC4 Series | ||||||
Each | 1+1 318,240 $ 3+1 249,170 $ 5+1 180,100 $ 10+1 155,720 $ | PL e | Level 4 | SIL3, SIL CL3 | 2 | 510mm | 20m | IP65, IP67 | - | CE, UKCA, cULus, TUV | 500mm | 2PNP | 24VDC | SLC4 Series | ||||||
Each | 1+2 021,230 $ 3+1 952,300 $ 5+1 883,360 $ | PL c | Level 2 | SIL1, SIL CL1 | 68 | 1.36m | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC2 Series | ||||||
Each | 1+1 768,890 $ 3+1 731,050 $ 5+1 693,220 $ | PL e | Level 4 | SIL3, SIL CL3 | 38 | 760mm | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC4 Series | ||||||
05AN2643 | Each | 1+1 547,000 $ 5+1 470,010 $ | PL e | Level 4 | SIL3 | 16 | 320mm | 20m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 20mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
05AN2657 | Each | 1+2 991,740 $ 5+2 914,850 $ | PL e | Level 4 | SIL3 | 56 | 1.12m | 20m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 20mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
05AN2640 | Each | 1+1 948,600 $ 5+1 481,130 $ | PL e | Level 4 | SIL3 | 23 | 240mm | 10m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 10mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
Each | 1+1 406,910 $ 3+1 349,190 $ 5+1 291,470 $ 10+1 257,450 $ | PL e | Level 4 | SIL3, SIL CL3 | 23 | 460mm | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC4 Series | ||||||
Each | 1+2 562,590 $ 3+2 558,400 $ 5+2 554,200 $ | PL e | Level 4 | SIL3, SIL CL3 | 68 | 1.36m | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC4 Series | ||||||
05AN2652 | Each | 1+2 451,980 $ 5+2 389,220 $ | PL e | Level 4 | SIL3 | 22 | 880mm | 20m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 40mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
Each | 1+1 381,510 $ 3+1 309,590 $ 5+1 237,670 $ 10+1 210,870 $ | PL c | Level 2 | SIL1, SIL CL1 | 38 | 760mm | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC2 Series | ||||||
Each | 1+3 196,630 $ 3+3 191,110 $ 5+3 185,590 $ | PL e | Level 4 | SIL3, SIL CL3 | 91 | 1.81m | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | - | 2PNP | 24VDC | SLC4 Series | ||||||
05AN2641 | Each | 1+1 388,700 $ 5+1 312,870 $ | PL e | Level 4 | SIL3 | 12 | 240mm | 20m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 20mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
Each | 1+845,150 $ 3+795,710 $ 5+746,270 $ 10+730,050 $ | PL c | Level 2 | SIL1, SIL CL1 | 2 | 510mm | 12m | IP65, IP67 | - | CE, UKCA, cULus, TUV | 500mm | 2PNP | 24VDC | SLC2 Series | ||||||
05AN2664 | Each | 1+1 912,070 $ 5+1 816,480 $ | PL e | Level 4 | SIL3 | 55 | 560mm | 10m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 10mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||
05AN2660 | Each | 1+3 639,730 $ | PL e | Level 4 | SIL3 | 76 | 1.52m | 20m | IP65, IP67, IP67G | - | ISO 13849, IEC 61496, IEC 61508, EN ISO 13849, EN 61496, EN 61508, CSA C22.2 No.14, UL 61496 | 20mm | NPN / PNP | 24VDC | F3SG-SR Series | |||||



