Air Quality & Gas Sensors :
81 produit(s) trouvé(s)Tous les filtres
(1 Appliqués)
Tout développer
Fabricant
(81)
Operating Temperature Min
=0°C
1
(40)
(3)
(15)
(3)
(81)
(9)
Sensor Type / Technology
(57)
Media Type
(78)
(3)
Output Interface
(1)
(1)
(2)
(16)
(1)
(1)
(1)
(1)
Measurement Range
(3)
(67)
Sampling Method
(23)
(1)
(38)
(15)
Supply Voltage Min
(5)
(3)
(61)
(1)
(7)
Supply Voltage Max
(4)
(7)
(3)
(66)
(1)
Sensor Case / Package
(24)
Sensor Mounting
(1)
(8)
(72)
Emballage
(81)
| Comparer | Réf. fabricant | Code Commande | Fabricant / Description | Disponibilité | Prix pour | Prix | Quantité | Sensor Type / Technology | Media Type | Output Interface | Measurement Range | Sampling Method | Supply Voltage Min | Supply Voltage Max | Sensor Case / Package | Sensor Mounting | Operating Temperature Min | Operating Temperature Max | Product Range |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | 1+779,800 $ | Gas Sensor | Carbon Dioxide | Analogue - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion | 16.5VDC | 40VDC | - | Duct Mount | 0°C | 50°C | CO2 DUCT Series | ||||||
Each | 1+1 454,600 $ | Gas Sensor | Carbon Dioxide | Analogue - 0VDC to 10VDC / Digital - Modbus RTU, BACnet MS/TP | 0 to 2000ppm | Non-dispersive Infrared (NDIR) | 19.2V | 28.8V | - | Wall Mount | 0°C | 50°C | tSENSE Series | ||||||
Each | 1+561,400 $ | Gas Sensor | Carbon Dioxide | Analogue - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 ROOM Series | ||||||
Each | 1+725,200 $ | - | Carbon Dioxide | 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC - Field Selectable | 0 to 2000ppm | Diffusion | 16.5VDC | 40VDC | Module | Wall Mount | 0°C | 50°C | A/CO2-R2SO Series | ||||||
Each | 1+631,400 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+631,400 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+599,200 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+631,400 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
48AM1321 | Each | 1+506,840 $ 5+492,620 $ 10+460,560 $ 25+451,350 $ 50+442,130 $ | Gas Sensor | Carbon Dioxide | - | - | Diffusion | 16.5VDC | 40VDC | - | Duct Mount | 0°C | 50°C | CO2 DUCT Series | |||||
Each | 1+631,400 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+956,200 $ | Gas Sensor | Metal Oxide | Analog, RS485 Modbus | 0 to 1000ppb | - | 16VDC | 35VDC | - | Wall Mount | 0°C | 50°C | VOC Series | ||||||
Each | 1+693,000 $ | - | Carbon Dioxide | 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC - Field Selectable | 0 to 2000ppm | Diffusion | 16.5VDC | 40VDC | Module | Wall Mount | 0°C | 50°C | A/CO2-R2SO Series | ||||||
Each | 1+1 005,200 $ | - | Carbon Dioxide | Analog - 0V to 10V | 0 to 2000ppm | - | - | 24V | Module | Wall Mount | 0°C | 50°C | ESENSE-FAI Room Series | ||||||
Each | 1+599,200 $ | - | Carbon Dioxide | 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC - Field Selectable | 0 to 2000ppm | Diffusion | 16.5VDC | 40VDC | Module | Wall Mount | 0°C | 50°C | A/CO2-R2O Series | ||||||
Each | 1+631,400 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+599,200 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+599,200 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+631,400 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+1 050,000 $ | Gas Sensor | Carbon Dioxide | Analog - 0VDC to 10VDC, Digital - RS-232 | 0 to 2000ppm | Diffusion, Flow Through, Non-dispersive Infrared (NDIR) | 18VDC | 42VDC | - | Duct Mount | 0°C | 50°C | A/CO2-010 Series | ||||||
Each | 1+631,400 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+599,200 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+564,200 $ | Gas Sensor | Carbon Dioxide | Analog - 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC | 0 to 2000ppm | Diffusion, Non-dispersive Infrared (NDIR) | 16.5VDC | 40VDC | - | Wall Mount | 0°C | 50°C | CO2 Room Series | ||||||
Each | 1+631,400 $ | - | Carbon Dioxide | 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC - Field Selectable | 0 to 2000ppm | Diffusion | 16.5VDC | 40VDC | Module | Wall Mount | 0°C | 50°C | A/CO2-R2SO Series | ||||||
Each | 1+549,190 $ 5+534,690 $ 10+501,940 $ 25+492,550 $ 50+483,130 $ | Gas Sensor | Carbon Dioxide | - | - | Non-dispersive Infrared (NDIR) | 19.2V | 28.8V | - | Wall Mount | 0°C | 50°C | eSENSE Series | ||||||
Each | 1+581,000 $ | - | Carbon Dioxide | 4mA to 20mA, 0VDC to 5VDC, 0VDC to 10VDC - Field Selectable | 0 to 2000ppm | Diffusion | 16.5VDC | 40VDC | Module | Wall Mount | 0°C | 50°C | A/CO2-R2O Series | ||||||






