Imprimer la page
L'image a des fins d'illustration uniquement. Veuillez lire la description du produit.
26 En Stock
| Quantité | Prix |
|---|---|
| 1+ | 148,010 $ |
| 10+ | 135,610 $ |
| 25+ | 133,850 $ |
| 50+ | 130,690 $ |
| 100+ | 122,560 $ |
| 250+ | 109,700 $ |
| 500+ | 97,400 $ |
Prix pour :Each
Minimum: 1
Multiple: 1
148,01 $
Note à la ligne
Ajouté à votre confirmation de commande, à votre facture et à votre note d’expédition pour cette commande uniquement.
Ce numéro sera ajouté à la confirmation de commande, à la facture, au bon d’expédition, au courriel de confirmation Web et à l’étiquette.
Informations produit
FabricantLEM
Réf. FabricantAT20B10
Code Commande99Y7860
Gamme de produitAT-B10 Series
Fiche technique
Sensor Output TypeAnalog
Supply Voltage Range-
Supply Voltage Range-
Measured CurrentAC
Accuracy± 1.5%
Current Sensor TechnologySplit-Core
Primary Current20A
Secondary Signal Type0V to 10V
Sensor Mounting-
Operating Temperature Min-20°C
Operating Temperature Max60°C
Product RangeAT-B10 Series
SVHCTo Be Advised
Aperçu du produit
AT 20 B10 is an AC current split-core transducer for the electronic measurement of AC waveform currents, with galvanic separation between the primary circuit and the secondary circuit. 0 to 10VDC switch voltage output proportional to the RMS value of the primary current. Applications includes automation and supervision-current measurement for process regulation by distributed PLCs or remote control (e.g. SCADA software), safety and condition monitoring-load monitoring for protection systems and predictive maintenance (e.g. conveyers, pumps or HVAC motors). Application domains are energy and automation.
- 10A IPN primary nominal RMS current (At RMS), 0 to 10VDC output voltage range
- RMS (average) output, split-core type, terminal output
- ⌀16mm sensing aperture for non-contact measurement
- Insulating plastic case recognized according to UL 94-V0
- High insulation between primary and secondary circuits
- Compact case, cost-effective solution, easy installation
- ≥ 2Mohm load resistance, self-powered supply voltage
- 50/60Hz frequency bandwidth, IP 40 protection degree
- Error is < ±1.5% of IPN at IP N, TA = 25°C (excluding offset)
- Ambient operating temperature range from -20 to +60°C
Spécifications techniques
Sensor Output Type
Analog
Supply Voltage Range
-
Accuracy
± 1.5%
Primary Current
20A
Sensor Mounting
-
Operating Temperature Max
60°C
SVHC
To Be Advised
Supply Voltage Range
-
Measured Current
AC
Current Sensor Technology
Split-Core
Secondary Signal Type
0V to 10V
Operating Temperature Min
-20°C
Product Range
AT-B10 Series
Documents techniques (2)
Législation et Questions environnementales
US ECCN:EAR99
EU ECCN:Unknown
Conforme RoHS :Oui
RoHS
Conforme à la norme RoHS Phthalates:Oui
RoHS
SVHC :To Be Advised
Télécharger le certificat de conformité du produit
Certificat de conformité du produit