| Fabricant | LEM |
|---|---|
| Réf. Fabricant | DVL 2000Copie |
| Délai d’approvisionnement standard du fabricant | 14 semaines |
| Code Commande | 99Y7927 |
| Gamme de produit | DVL Series |
| Votre numéro de pièce |
| Quantité | Prix |
|---|---|
| 1+ | 398,640 $ |
| 5+ | 397,170 $ |
| 10+ | 395,730 $ |
| 25+ | 394,260 $ |
| 50+ | 386,380 $ |
Informations produit

| Fabricant | LEM |
|---|---|
| Réf. Fabricant | DVL 2000Copie |
| Délai d’approvisionnement standard du fabricant | 14 semaines |
| Code Commande | 99Y7927 |
| Gamme de produit | DVL Series |
| Transducer Function | Voltage Transformer |
| Measured Voltage | AC, DC, Pulsed |
| Supply Voltage Min | -13.5V |
| Supply Voltage Max | 26.4V |
| Supply Voltage Range | ± 13.5V to ± 26.4V |
| Supply Voltage Range | ± 13.5V to ± 26.4V |
| Primary Voltage Nom | 2kV |
| Accuracy % | 0.5% |
| Accuracy | ± 1% |
| Secondary Signal Type | 50mA |
| Sensor Output Type | Analog |
| Input Current | -mA |
| External Depth | 100mm |
| Sensor Mounting | Panel Mount |
| Output Current Max | 75mA |
| Operating Temperature Min | -40°C |
| Output Current Max | 75mA |
| Linearity % | 0.5% |
| Operating Temperature Max | 85°C |
| Product Range | DVL Series |
| SVHC | No SVHC (25-Jun-2025) |
Aperçu du produit
DVL 2000 is a DVL series voltage transducer for the electronic measurement of DC, AC, pulsed voltage with galvanic separation between the primary and the secondary circuit. Suitable for AC variable speed and servo motor drives, static converters for dc motor drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS), power supplies for welding applications, renewable energy (solar and wind), single or three phase inverters, propulsion and braking choppers, propulsion converters, auxiliary converters, high power drives, substations applications.
- Bipolar and insulated measurement up to 3000V and primary nominal RMS voltage is 2000V typ
- Current output, 50mA typ secondary nominal RMS current, 75mA max secondary current
- Supply voltage range from ±13.5V to ±26.4V
- Input and output connections with M5 studs
- Compatible with AV 100 family
- Compact design, low consumption and low losses
- Good behavior under common mode variations
- Excellent accuracy (offset, sensitivity, linearity) and good delay time
- Low temperature variation and high immunity to external interferences
- Ambient operating temperature TA range from -40 to 85°C
Spécifications techniques
| Transducer Function | Voltage Transformer |
|---|---|
| Supply Voltage Min | -13.5V |
| Supply Voltage Range | ± 13.5V to ± 26.4V |
| Primary Voltage Nom | 2kV |
| Accuracy | ± 1% |
| Sensor Output Type | Analog |
| External Depth | 100mm |
| Output Current Max | 75mA |
| Output Current Max | 75mA |
| Operating Temperature Max | 85°C |
| SVHC | No SVHC (25-Jun-2025) |
| Measured Voltage | AC, DC, Pulsed |
|---|---|
| Supply Voltage Max | 26.4V |
| Supply Voltage Range | ± 13.5V to ± 26.4V |
| Accuracy % | 0.5% |
| Secondary Signal Type | 50mA |
| Input Current | -mA |
| Sensor Mounting | Panel Mount |
| Operating Temperature Min | -40°C |
| Linearity % | 0.5% |
| Product Range | DVL Series |
Législation et Questions environnementales
| US ECCN: | EAR99 |
|---|---|
| EU ECCN: | Unknown |
| Conforme RoHS : | Oui RoHS |
| Conforme à la norme RoHS Phthalates: | Oui RoHS |
| SVHC : | No SVHC (25-Jun-2025) |
| Télécharger le certificat de conformité du produit | Certificat de conformité du produit |