Imprimer la page
L'image a des fins d'illustration uniquement. Veuillez lire la description du produit.
563 En Stock
Quantité | Prix |
---|---|
1+ | 214,580 $ |
10+ | 184,300 $ |
25+ | 177,090 $ |
50+ | 169,240 $ |
100+ | 155,030 $ |
250+ | 135,400 $ |
Prix pour :Each
Minimum: 1
Multiple: 1
214,58 $
Ajouter Référence Interne / Note à la ligne
Ajouté à votre confirmation de commande, à votre facture et à votre note d’expédition pour cette commande uniquement.
Ce numéro sera ajouté à la confirmation de commande, à la facture, au bon d’expédition, au courriel de confirmation Web et à l’étiquette.
Informations produit
FabricantLEM
Réf. FabricantLF 310-S
Code Commande99Y8152
Gamme de produitLF310 Series
Fiche technique
Sensor Output TypeAnalog
Supply Voltage Range± 11.4V to ± 21V
Supply Voltage Range± 11.4V to ± 21V
Measured CurrentAC / DC / Pulsed
Accuracy± 0.2%
Current Sensor TechnologyClosed Loop Hall Effect
Primary Current300A
Secondary Signal Type150mA
Sensor MountingPanel Mount
Operating Temperature Min-40°C
Operating Temperature Max85°C
Product RangeLF310 Series
SVHCTo Be Advised
Aperçu du produit
LF 310-S is a current transducer. It is used for the for the electronic measurement of DC, AC, pulsed current with galvanic separation between the primary and the secondary circuit. Applications include windmill inverters, test and measurement, substations, AC variable speed and servo motor drives, statics converters for DC motors drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS).
- Bipolar and insulated current measurement up to 500A
- Current output, closed loop (compensated) current transducer
- Panel mounting, high accuracy, very low offset drift over temperature
- 100KHz typ frequency bandwidth at (RM = 50 ohm, -3dB)
- Supply voltage range from ±11.4V to ±21V
- 0.1% typ sensitivity error, 0.25A typ secondary current
- 0.5µs typ reaction time at 10% of IPN
- Linearity error is 0.05% of IPN typ
- Ambient temperature range from -40C to 85°C
- High accuracy and very low offset drift over temperature
Spécifications techniques
Sensor Output Type
Analog
Supply Voltage Range
± 11.4V to ± 21V
Accuracy
± 0.2%
Primary Current
300A
Sensor Mounting
Panel Mount
Operating Temperature Max
85°C
SVHC
To Be Advised
Supply Voltage Range
± 11.4V to ± 21V
Measured Current
AC / DC / Pulsed
Current Sensor Technology
Closed Loop Hall Effect
Secondary Signal Type
150mA
Operating Temperature Min
-40°C
Product Range
LF310 Series
Documents techniques (2)
Législation et Questions environnementales
US ECCN:EAR99
EU ECCN:Unknown
Conforme RoHS :Oui
RoHS
Conforme à la norme RoHS Phthalates:Oui
RoHS
SVHC :To Be Advised
Télécharger le certificat de conformité du produit