| Manufacturer | LEM |
|---|---|
| Manufacturer Part No | DVL 750Copy |
| Manufacturer Standard Lead Time | 14 weeks |
| Newark Part No. | 99Y7934 |
| Product Range | DVL Series |
| Your Part Number | |
| Technical Datasheet |
15 more incoming. You can reserve stock now
| Quantity | Price |
|---|---|
| 1+ | $432.760 |
| 5+ | $413.460 |
| 10+ | $403.180 |
| 25+ | $392.890 |
| 50+ | $369.980 |
Product Information
| Manufacturer | LEM |
|---|---|
| Manufacturer Part No | DVL 750Copy |
| Manufacturer Standard Lead Time | 14 weeks |
| Newark Part No. | 99Y7934 |
| Product Range | DVL Series |
| Technical Datasheet | |
| Transducer Function | Voltage Transformer |
| Measured Voltage | AC, DC, Pulsed |
| Supply Voltage Min | -13.5V |
| Supply Voltage Range | ± 13.5V to ± 26.4V |
| Supply Voltage Range | ± 13.5V to ± 26.4V |
| Supply Voltage Max | 26.4V |
| Accuracy % | 0.5% |
| Primary Voltage Nom | 750VAC |
| Accuracy | 0.5% |
| Secondary Signal Type | Current |
| Sensor Output Type | Analog |
| Input Current | -mA |
| External Depth | 100mm |
| Sensor Mounting | Panel Mount |
| Operating Temperature Min | -40°C |
| Output Current Max | 75mA |
| Output Current Max | 75mA |
| Linearity % | 0.5% |
| Operating Temperature Max | 85°C |
| Product Range | DVL Series |
| SVHC | No SVHC (25-Jun-2025) |
Product Overview
DVL 750 is a voltage transducer for the electronic measurement of voltage: DC, AC, pulsed with galvanic separation between the primary and the secondary circuit. Applications include AC variable speed and servo motor drives, static converters for DC motor drives, battery supplied applications, UPS, SMPS, power supplies for welding applications, renewable energy (solar and wind), single or three phase inverters, propulsion and braking choppers, propulsion converters, auxiliary converters, high power drives and substations.
- Bipolar and insulated measurement up to 1125V, current output
- Input connection with M5 studs, compatible with AV 100 family
- Connection to secondary circuit on SMS6GE6 Burndy connector
- Low consumption and low losses, compact design
- Good behavior under common mode variations, excellent accuracy (offset, sensitivity, linearity)
- Good delay time, low temperature variation
- High immunity to external interferences
- Supply voltage range from ±13.5 to ±26.4V (TA = 25°C, ±UC = ±24V, RM = 100 ohm)
- Primary nominal RMS voltage is 750V typ (TA = 25°C, ±UC = ±24V, RM = 100 ohm)
- Ambient operating temperature range from -40 to 85°C
Technical Specifications
| Transducer Function | Voltage Transformer |
|---|---|
| Supply Voltage Min | -13.5V |
| Supply Voltage Range | ± 13.5V to ± 26.4V |
| Accuracy % | 0.5% |
| Accuracy | 0.5% |
| Sensor Output Type | Analog |
| External Depth | 100mm |
| Operating Temperature Min | -40°C |
| Output Current Max | 75mA |
| Operating Temperature Max | 85°C |
| SVHC | No SVHC (25-Jun-2025) |
| Measured Voltage | AC, DC, Pulsed |
|---|---|
| Supply Voltage Range | ± 13.5V to ± 26.4V |
| Supply Voltage Max | 26.4V |
| Primary Voltage Nom | 750VAC |
| Secondary Signal Type | Current |
| Input Current | -mA |
| Sensor Mounting | Panel Mount |
| Output Current Max | 75mA |
| Linearity % | 0.5% |
| Product Range | DVL Series |
Technical Docs (3)
Legislation and Environmental
| US ECCN: | EAR99 |
|---|---|
| EU ECCN: | Unknown |
| RoHS Compliant: | Yes RoHS |
| RoHS Phthalates Compliant: | Yes RoHS |
| SVHC: | No SVHC (25-Jun-2025) |
| Download Product Compliance Certificate | Product Compliance Certificate |