Imprimer la page
L'image a des fins d'illustration uniquement. Veuillez lire la description du produit.

FabricantLEM
Réf. FabricantDVL 750Copie
Code Commande99Y7934
Gamme de produitDVL Series
Votre numéro de pièce
51 En Stock
| Quantité | Prix |
|---|---|
| 1+ | 499,880 $ |
| 5+ | 426,320 $ |
| 10+ | 394,890 $ |
| 25+ | 363,480 $ |
Prix pour :Each
Minimum: 1
Multiple: 1
499,88 $
Note à la ligne
Ajouté à votre confirmation de commande, à votre facture et à votre note d’expédition pour cette commande uniquement.
Informations produit
FabricantLEM
Réf. FabricantDVL 750Copie
Code Commande99Y7934
Gamme de produitDVL Series
Fiche technique
Transducer FunctionVoltage Transformer
Measured VoltageAC, DC, Pulsed
Supply Voltage Min-13.5V
Supply Voltage Range± 13.5V to ± 26.4V
Supply Voltage Max26.4V
Supply Voltage Range± 13.5V to ± 26.4V
Primary Voltage Nom750VAC
Accuracy %0.5%
Accuracy0.5%
Secondary Signal TypeCurrent
Input Current-mA
Sensor Output TypeAnalog
External Depth100mm
Sensor MountingPanel Mount
Output Current Max75mA
Operating Temperature Min-40°C
Output Current Max75mA
Operating Temperature Max85°C
Linearity %0.5%
Product RangeDVL Series
SVHCNo SVHC (25-Jun-2025)
Aperçu du produit
DVL 750 is a voltage transducer for the electronic measurement of voltage: DC, AC, pulsed with galvanic separation between the primary and the secondary circuit. Applications include AC variable speed and servo motor drives, static converters for DC motor drives, battery supplied applications, UPS, SMPS, power supplies for welding applications, renewable energy (solar and wind), single or three phase inverters, propulsion and braking choppers, propulsion converters, auxiliary converters, high power drives and substations.
- Bipolar and insulated measurement up to 1125V, current output
- Input connection with M5 studs, compatible with AV 100 family
- Connection to secondary circuit on SMS6GE6 Burndy connector
- Low consumption and low losses, compact design
- Good behavior under common mode variations, excellent accuracy (offset, sensitivity, linearity)
- Good delay time, low temperature variation
- High immunity to external interferences
- Supply voltage range from ±13.5 to ±26.4V (TA = 25°C, ±UC = ±24V, RM = 100 ohm)
- Primary nominal RMS voltage is 750V typ (TA = 25°C, ±UC = ±24V, RM = 100 ohm)
- Ambient operating temperature range from -40 to 85°C
Spécifications techniques
Transducer Function
Voltage Transformer
Supply Voltage Min
-13.5V
Supply Voltage Max
26.4V
Primary Voltage Nom
750VAC
Accuracy
0.5%
Input Current
-mA
External Depth
100mm
Output Current Max
75mA
Output Current Max
75mA
Linearity %
0.5%
SVHC
No SVHC (25-Jun-2025)
Measured Voltage
AC, DC, Pulsed
Supply Voltage Range
± 13.5V to ± 26.4V
Supply Voltage Range
± 13.5V to ± 26.4V
Accuracy %
0.5%
Secondary Signal Type
Current
Sensor Output Type
Analog
Sensor Mounting
Panel Mount
Operating Temperature Min
-40°C
Operating Temperature Max
85°C
Product Range
DVL Series
Documents techniques (3)
Législation et Questions environnementales
US ECCN:EAR99
EU ECCN:Unknown
Conforme RoHS :Oui
RoHS
Conforme à la norme RoHS Phthalates:Oui
RoHS
SVHC :No SVHC (25-Jun-2025)
Télécharger le certificat de conformité du produit