| Manufacturer | TRIAD MAGNETICS |
|---|---|
| Manufacturer Part No | N68XCopy |
| Manufacturer Standard Lead Time | 8 weeks |
| Newark Part No. | 18M9252 |
| Product Range | N Series |
| Your Part Number | |
| Technical Datasheet |
Need more?
| Quantity | Price |
|---|---|
| 1+ | $38.990 |
| 5+ | $37.560 |
| 10+ | $36.130 |
| 25+ | $35.860 |
| 50+ | $35.510 |
| 100+ | $35.170 |
| 250+ | $34.040 |
| 5000+ | $32.290 |
Product Information
| Manufacturer | TRIAD MAGNETICS |
|---|---|
| Manufacturer Part No | N68XCopy |
| Manufacturer Standard Lead Time | 8 weeks |
| Newark Part No. | 18M9252 |
| Product Range | N Series |
| Technical Datasheet | |
| Chassis Mount Transformer Type | Safety Isolating |
| Secondary Voltages | 115V |
| Primary Voltages | 2 x 115V |
| Power Rating | 50VA |
| Frequency Range | 50Hz / 60Hz |
| Winding Type | Dual Primary, Single Secondary |
| Current Rating | 435mA |
| Transformer Terminals | Wire Leaded |
| Isolation Voltage | 1.5kV |
| Product Range | N Series |
| SVHC | No SVHC (25-Jun-2025) |
Product Overview
The N68X is an Isolation Power Transformer for isolating equipment from direct connection to the power line. The transformer is constructed with non-concentrically wound coils. The primary and secondary are wound on separate arbors, then assembled on a laminate core side-by-side separated by insulation. This prevents electrical connection, under normal or overload conditions, between the primary and secondary windings. These hospital type units are offered with a resettable circuit breaker, providing protection from overload and short circuit. Triad isolation transformer is also offered in hospital type (designed with an MD suffix) which are designed and constructed to meet the low leakage current requirements for today's medical equipment.
- Constructed with non-concentrically wound coil
- Leads connections
Applications
Power Management
Technical Specifications
| Chassis Mount Transformer Type | Safety Isolating |
|---|---|
| Primary Voltages | 2 x 115V |
| Frequency Range | 50Hz / 60Hz |
| Current Rating | 435mA |
| Isolation Voltage | 1.5kV |
| SVHC | No SVHC (25-Jun-2025) |
| Secondary Voltages | 115V |
|---|---|
| Power Rating | 50VA |
| Winding Type | Dual Primary, Single Secondary |
| Transformer Terminals | Wire Leaded |
| Product Range | N Series |