| Fabricant | TRIAD MAGNETICS |
|---|---|
| Réf. Fabricant | VPL36-1400Copie |
| Délai d’approvisionnement standard du fabricant | 27 semaines |
| Code Commande | 70M7631 |
| Gamme de produit | VPL Series |
| Votre numéro de pièce | |
| Fiche technique |
| Quantité | Prix |
|---|---|
| 1+ | 48,190 $ |
| 5+ | 46,020 $ |
| 10+ | 44,720 $ |
| 25+ | 43,830 $ |
| 50+ | 42,920 $ |
| 100+ | 42,030 $ |
Informations produit
| Fabricant | TRIAD MAGNETICS |
|---|---|
| Réf. Fabricant | VPL36-1400Copie |
| Délai d’approvisionnement standard du fabricant | 27 semaines |
| Code Commande | 70M7631 |
| Gamme de produit | VPL Series |
| Fiche technique | |
| Chassis Mount Transformer Type | Split Bobbin |
| Primary Voltages | 115V, 230V |
| Secondary Voltages | 2 x 18 |
| Power Rating | 50VA |
| Frequency Range | 50Hz / 60Hz |
| Winding Type | Dual Primary, Dual Secondary |
| Current Rating | 2.778A |
| Transformer Terminals | Wire Leaded |
| Isolation Voltage | 3.5kV |
| Product Range | VPL Series |
| SVHC | No SVHC (25-Jun-2025) |
Aperçu du produit
The International series 5VA chassis-mount Power Transformer with 230VAC series/115VAC parallel @ 50/60Hz primary and 24V CT @ 0.21A series/12V CT @ 0.42A parallel secondary. The dual winding construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements. Shrouds are provided over the connections of the leads to the windings on both primary and secondary coils. Devices are designed with a minimum of 6mm creepage distance between the primary and secondary and are manufactured with a Class-B (130°C) insulation system.
- 20% Voltage regulation at full load to no load
- 3500VAC Hi-pot between primary to secondary and windings to core
Applications
Power Management, Industrial
Spécifications techniques
| Chassis Mount Transformer Type | Split Bobbin |
|---|---|
| Secondary Voltages | 2 x 18 |
| Frequency Range | 50Hz / 60Hz |
| Current Rating | 2.778A |
| Isolation Voltage | 3.5kV |
| SVHC | No SVHC (25-Jun-2025) |
| Primary Voltages | 115V, 230V |
|---|---|
| Power Rating | 50VA |
| Winding Type | Dual Primary, Dual Secondary |
| Transformer Terminals | Wire Leaded |
| Product Range | VPL Series |
Documents techniques (1)
Législation et Questions environnementales
| US ECCN: | EAR99 |
|---|---|
| EU ECCN: | Unknown |
| Conforme RoHS : | Oui RoHS |
| Conforme à la norme RoHS Phthalates: | Oui RoHS |
| SVHC : | No SVHC (25-Jun-2025) |
| Télécharger le certificat de conformité du produit | Certificat de conformité du produit |