Print Page
Image is for illustrative purposes only. Please refer to product description.
ManufacturerLEM
Manufacturer Part NoDVL 50
Newark Part No.99Y7930
Product RangeDVL Series
Technical Datasheet
Available to Order
Manufacturer Standard Lead Time: 13 week(s)
Quantity | Price |
---|---|
1+ | $418.100 |
5+ | $404.510 |
10+ | $385.780 |
25+ | $367.010 |
50+ | $318.490 |
Price for:Each
Minimum: 1
Multiple: 1
$418.10
Enter Your Part No/Line Note
Added to your Order Confirmation, Invoice, and Dispatch note for this order only.
This number will be added to the Order Confirmation, Invoice, Dispatch note, Web confirmation Email and Product Label.
Product Information
ManufacturerLEM
Manufacturer Part NoDVL 50
Newark Part No.99Y7930
Product RangeDVL Series
Technical Datasheet
Transducer FunctionVoltage Transformer
Supply Voltage Min-13.5V
Measured VoltageAC, DC, Pulsed
Supply Voltage Range± 13.5V to ± 26.4V
Supply Voltage Max26.4V
Accuracy0.5%
Primary Voltage Nom50V
Accuracy± 0.5%
Secondary Signal Type50mA
Input Current-mA
Sensor Output TypeAnalog
Sensor MountingPanel Mount
External Depth100mm
Output Current Max75mA
Operating Temperature Min-40°C
Output Current Max75mA
Operating Temperature Max85°C
Linearity %0.5%
Product RangeDVL Series
SVHCTo Be Advised
Product Overview
DVL 50 is a voltage transducer for the electronic measurement of voltage: DC, AC, pulsed with galvanic separation between the primary and the secondary circuit. Approved by EN 50155: 2007, EN 50178: 1997, EN 50124-1: 2001, EN 50121-3-2: 2006, UL 508: 2013 and IEC 61010-1: 2010 standards. Typical applications include single or three phase inverters, propulsion and braking choppers, propulsion converters, auxiliary converters, high power drives and substations.
- Bipolar and insulated measurement up to 75V
- Measuring resistance is 133ohm max
- Current output
- Input and output connections with M5 studs
- Compatible with AV 100 family
- Low consumption and low losses
- Compact design
- Excellent accuracy (offset, sensitivity, linearity)
- Good response time, low temperature drift
- High immunity to external interferences
Technical Specifications
Transducer Function
Voltage Transformer
Measured Voltage
AC, DC, Pulsed
Supply Voltage Max
26.4V
Primary Voltage Nom
50V
Secondary Signal Type
50mA
Sensor Output Type
Analog
External Depth
100mm
Operating Temperature Min
-40°C
Operating Temperature Max
85°C
Product Range
DVL Series
Supply Voltage Min
-13.5V
Supply Voltage Range
± 13.5V to ± 26.4V
Accuracy
0.5%
Accuracy
± 0.5%
Input Current
-mA
Sensor Mounting
Panel Mount
Output Current Max
75mA
Output Current Max
75mA
Linearity %
0.5%
SVHC
To Be Advised
Technical Docs (2)
Legislation and Environmental
US ECCN:EAR99
EU ECCN:Unknown
RoHS Compliant:Yes
RoHS
RoHS Phthalates Compliant:Yes
RoHS
SVHC:To Be Advised
Download Product Compliance Certificate
Product Compliance Certificate